All
burners require a mixture of fuel and air in order to work properly. This
mixture can be supplied by use of an Inspirators, using the gas pressure
to induce an air flow, or through a Fueljector, wherein the air pressure
induces a gas flow. This second system can be constructed with either an
air supply from compressed air and an Inspirators or with a blower. The
use of a blower allows the system to operate independent of the availability
of shop air. This system can be built for as little as 2 burners, up to
20 or more.
Each burner would be equipped with its own flame
safety control, with the gas solenoids prepiped on the system. Air and gas
mixture are adjustable independently on each burner. The combustion air
blower is provided with an air filter. The electrical panel is wired for
either 208/230V or 460V 3Ø. All systems of 100,000 BTU's or more are provided
with dual gas safety valves, pressure regulator, zero gas regulator, high
and low gas pressure switches, as well as a proof of closure switch for
IRI requirements. The entire system is built to allow replacement of parts
without dismantling the entire gas train.
Click on the picture to enlarge.
Unit Shown
Dimensions
32" Deep X 32" Wide X 40" Height
Electrical Power
230/460V 3Ø 60Hz
Capacity
240,000 BTU's
Gas Connection
1".
|